Electrical. Brass ball valve, G 3/8", 85 to 240 V (AC/DC) (Sanitation)

KH 38 ELS 230

Exemplary representation: Kugelhahn mit elektrischem Schwenkantrieb (Sanitärausführung)
421,05€ incl. VAT
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.beschreibung_headline') }}
Advantages:
•2 additional limit switches,
•torque cut-off,
•variable voltage (DC or AC),
•manual emergency operation,
•integrated heating in actuator housing


Ball valve


Materials:
Housing: nickel-plated brass, ball: hard chromium plated brass, seal: PTFE / FKM

Temperature range:
-20°C to +95°C

Media:
Water, compressed air, vacuum (max. -0.9 bar), oils, fuels, heating oil, solvents, colours, paints, weak acids and alkalis

Rotary actuator


Description:
Electrical rotary actuator with optical position indicator, manual emergency operation and switch room heating Two additional limit switches are installed for further control requirements. An electronic torque limiting unit prevents damage in the event of overload. The manual emergency operation can be done without dismantling the external cladding. Do not use upside down!

Temperature range:
-20°C to +70°C

Voltage:
Type 230: 85 - 240 V AC/DC, type 24: 24 V AC/DC, (actuators can be operated with AC and DC voltage).

Protection class:
IP 65

Max. switchable pressure difference:
16 bar

Power-on time:
75%

Warning:
In case of high media temperatures, the actuator must be cooled if necessary!
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Voltage 85 - 240 V (AC/DC)
Thread G 3/8"
DN [mm] 15
Installation length ball valve [mm] 64
PN* [bar] -0,9 to 40
Regulating time [s] 16
Spare drives ELS 230-1
KH38ELS230
{{ $t('shop.all.gewicht') }} 1,3 kg / pcs
{{ $t('shop.all.gtin') }} 4050571421106
{{ $t('shop.display.artikel.zollwarennummer') }} 84818081
{{ $t('shop.display.artikel.rohskonform') }} {{ $t('shop.all.ja') }}
{{ $t('shop.all.dokumente') }}
    Catalogue page Atlas 9 (Page 538) atlas9_seiten/538.pdf
    Documentation: electrically actuated ball valves doku/kheli.pdf
    Function and structure of an electrical ball valve
  • {{ $t('shop.display.datenblatt.titel') }} (Print view)
*Max. switchable pressure difference: 16 bar
 
{{ $t('shop.all.unverbindliche_richtwerte') }}

Accessories

Payment options:
{{ $t('shop.all.spaetbestellservice') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.

  • {{ $t(error) }}