Data sheet

pneumatic sensor fitting G 1/8", Internal thread (pneumatic signal output)
{{ $t('shop.all.artikelnummer') }}:
PPL 18
Example illustration
{{ $t('shop.display.artikel.beschreibung_headline') }}
Materials:
Body: Brass, nickel-plated brass, plastic, seals: NBR
Switching time:
3 ms
Electrical connection values (Type PPE):
max. 2 A, 0 - 48 V DC, 250 V AC
Power consumption (PPE type):
Direct current: 5 W, alternating current: 10 VA
Protection class (PPE type):
IP 40
Function:
A pneumatic sensor fitting takes over the function of the limit switch (pneumatic or electric signal). The screw connection is screwed into the input hole of a cylinder and scans the working pressure of the cylinder. If the screw connection shows no pressure, the screw connection switches over from (P) 1 to (S) 5.
Warning:
Signal screw connections detect reaching the end position only through a pressure drop. However, this pressure drop can also occur if the cylinder is blocked in its movement path. If there is danger of such a blockage, we recommend using pneumatic cylinder switches, which react directly to the magnetic field of a magnetic piston.
Advantages:
•pure pneumatic control, no electrical energy required,
•simple installation,
•compact design
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Signal connection version Internal thread (pneumatic signal output)
External thread G 1/8"
Female thread G 1/8"
Signal connection (internal thread) M 5
Temperature range [°C] -15 to +60
Operating pressure [bar] 3 - 8
reaction pressure [bar] 0,6
Further information:
{{ $t('shop.all.gewicht') }} 49 g / pcs
{{ $t('shop.all.gtin') }} 4050571549992
{{ $t('shop.display.artikel.zollwarennummer') }} 84818099
{{ $t('shop.display.artikel.rohskonform') }} {{ $t('shop.all.ja') }}
Figure
Drawing:
Drawing: Functional principle of signal screw connection (cylinder in motion)
Drawing: Functional principle of signal screw connection (cylinder in end position)
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 08.12.2025