Data sheet

Digital pressure gauge 0 to 1600 bar, Continuous operation
{{ $t('shop.all.artikelnummer') }}:
DMGB 1600 ES-D
Example illustration
{{ $t('shop.display.artikel.beschreibung_headline') }}
Suitable:
Wherever a high measurement accuracy along with a high overpressure safety and sturdiness is required. For example, for calibration of pressure gauges (using the hand pump HP 40).
Materials:
Housing: plastic, connection: 1.4571, seal: NBR: (>= 1000 bar: 1.4571), Sensor: Ceramic (>= 1000 bar: 1.4571)
Display:
4-digit LCD display, height of digits: 12.7 mm
Connection thread:
G 1/4" * (>= 1000 bar: G 1/2" *)
Temperature range:
Ambient conditions: 0 to +60 °C, measured material: -30 to +85 °C
Permissible overpressure:
up to 40 bar 3 x, up to 160 bar: 2 x, from 250 bar onwards: 1.5 x full scale value** (violating the lower measurement value is not permitted)
Class:
0,5
Conversion rate:
5 measurements / second
Automatic shut-off time:
8 min.
Auxiliary energy:
9V block battery, service life: 5,000 h
Protection class:
IP 65
Optional:
Continuous operation -D, deviating switch-off times -4, -16, -32, -64., continuous operation with external 24 V DC supply (M 12 connector, A-coded, 4-pin, 4-wire) -D24, continuous operation with external 24 V DC supply and additional switching output (30 V AC/DC, max. 2 A, M 12 connector, A-coded, 5-pin, 5-wire) -D24S, ISO factory calibration (following DIN EN 837-1, determination of measurement deviation and hysteresis), DAkkS-DKD calibration (in accordance with DKD-R 6-1, traceable and accredited in accordance with DIN EN ISO/IEC 17025, decision rule 4)
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Display range [bar] 0 - 1600
Connection thread G 1/2"
Version Continuous operation
Overpressuresafe [bar] 0 - 2400
Further information:
{{ $t('shop.all.gewicht') }} 420 g / pcs
{{ $t('shop.all.gtin') }} 4050571251123
{{ $t('shop.display.artikel.zollwarennummer') }} 90262040
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 08.12.2025