Data sheet

SOPA-CM2H-R1-WQ6-2P-M12 (552139) Air gap sensor
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO025202
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Permission RCM mark,
c UL us - Recognized (OL)
CE certificate (see declaration of conformity) acc. to EU-EMV Directive,
acc. to EU-RoHS Directive
KC-mark KC-EMV
Material information Copper and PTFE-free,
RoHs compliant
Detected variable Abstand
Measurement principle pneumatic
Recording range [µm] 20 to 200
Operating pressure [bar] 4 to 7
Feed pressure [bar] 0.8 to 1.6
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Information about operating and control medium Oiled operation possible (required in further operations)
ambient temperature [°C] 0 to 50
Repetition accuracy in ± µm [µm] 2,5
Control output 2xPNP
Switch function Fenster-Komparator,
Schwellwert mit variabler Hysterese
Switching element function Opener/closer switchable
Max. output current [mA] 100
Short circuit resistance yes
Operating voltage range DC [V] 22.8 to 26.4
Reverse polarity protection for all electrical connections
Electrical connection 1, connection type Plug
Electrical connection 1, connection technology M12x1 A coded to EN 61076-2-101
Electrical connection 1, number of pins / wires 5
Electrical connection 1, fastening type Screw lock
Fastening type With throughway bores,
With Slot rail,
With Wall / flat holder,
Selectively:
Pneumatic connection QS-6
Housing material PA-verstärkt,
Aluminium eloxiert
Display type Illuminating LCD Multiple
Setting options Teach-in,
Via display and buttons
Tamper-proof fuse Electronic locking
Protection category IP65
Corrosion resistant class KBK 2 - moderate corrosion stress
Further information:
{{ $t('shop.all.gewicht') }} 650 g / pcs
{{ $t('shop.all.gtin') }} 4052568193751
{{ $t('shop.display.artikel.zollwarennummer') }} 90318020
{{ $t('shop.all.hersteller') }} Festo