Data sheet

SOE4-FO-D-HF2-1PU-K (552801) Fibre-optic unit
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO026184
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Design Block structure
Complies to standard EN 60947-5-2
Permission RCM mark,
c UL us - Listed (OL)
CE certificate (see declaration of conformity) to EU EMC directive
Material information Copper and PTFE-free
UKCA marking (see declaration of conformity) Position
Measurement principle Optoelectronic
Measurement process Light guide device
Light type red
Counter influence Protected,
Up to four direct side-by-side mounted devices
ambient temperature [°C] -20 to 60
Control output PNP
Switching element function Switchable
Max. switching frequency [Hz] Standard mode 1000 Hz,
Fine Mode 125 Hz,
Fast mode 8000 Hz,
High distance mode 125 Hz
Max. output current [mA] 100
Voltage drop [V] <= 2,4 V
Timer function 1 - 2000 ms
Short circuit resistance Cycling
Operating voltage range DC [V] 10 to 30
residual ripple 10 %
Empty run current [mA] <= 25 mA
Reverse polarity protection for all electrical operating voltage connections
Electrical connection 5-wire,
cable
Cable length [MTR] 2
Cable sleeve material TPE-U(PUR)
Fastening type With throughway bores,
With Slot rail
installation position arbitrary
Housing material ABS
Display LED - display
Switching status indicator LED yellow
Setting options Teach-in,
teach-in via electrical connection
Ambient temperature for moving cable placements [°C] -5 to 60
Protection category IP64
Insulation voltage [V] 50
Corrosion resistant class KBK 4 - particularly severe corrosion stress
Display 0000 - 4093
LABS (PWIS) conformity LED green
Analogue output 0 - 10 V
Further information:
{{ $t('shop.all.gewicht') }} 95 g / pcs
{{ $t('shop.all.gtin') }} 4052568194567
{{ $t('shop.display.artikel.zollwarennummer') }} 85365019
{{ $t('shop.all.hersteller') }} Festo
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 08.12.2025