Data sheet

SMAT-8M-U-E-0,3-M8D (553744) Position transmitter
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO027032
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Design For T-slot
Permission RCM mark,
c UL us - Listed (OL)
CE certificate (see declaration of conformity) to EU EMC directive
KC-mark KC-EMV
UKCA marking (see declaration of conformity) halogen free,
RoHs compliant
Material information Magnetic
Path measurement range [mm] <= 40 mm
ambient temperature [°C] -25 to 75
Sampling interval type [ms] 2,8
Max. movement speed [m/s] 3
Resolution travel [mm] <= 0,05 mm
Repeatability in ± mm [mm] 0,2
Analogue output 0 - 10 V
Linearity error typical in ± mm ± 0.2 mm on grippers,
± 1 mm on cylinders
Short circuit resistance yes
Overload resistant Available
Operating voltage range DC [V] 15 to 30
Reverse polarity protection for all electrical connections
Electrical connection 1, connection type Cable with plug
Electrical connection 1, connection technology M8x1 A coded to EN 61076-2-104
Electrical connection 1, number of pins / wires 4
Electrical connection 1, fastening type Screw lock
Cable sleeve material TPE-U(PUR)
Housing material PA6 reinforced
Status display LED red, green
Protection category IP65,
IP68
Corrosion resistant class KBK 2 - moderate corrosion stress
output signal Analogue
Test conditions line Bending radius strength to Festo standard,
Test conditions on request,
Torsional strength > 300,000 cycles, ±270°/0.1 m,
Cable track: 50,000 cycles, bending radius 30 mm
Cable length [MTR] 0,3
Line properties Cable track+robot
Fastening type Insertable from above into the slot,
Permanently screwed
Ambient temperature for moving cable placements [°C] -5 to 70
Further information:
{{ $t('shop.all.gewicht') }} 21 g / pcs
{{ $t('shop.all.gtin') }} 4052568197711
{{ $t('shop.display.artikel.zollwarennummer') }} 90318020
{{ $t('shop.all.hersteller') }} Festo
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 08.12.2025