Data sheet

EMMS-AS-140-S-HV-RR-S1 (1574644) servo motor
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO038053
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
ambient temperature [°C] -40 to 40
Bearing temperature [°C] -20 to 60
Relative humidity 0 - 90 %
Complies to standard IEC 60034
Insulation protection class F
Measurement class according to DIN 60034-1 S1
Temperature monitoring PTC resistance
Protection category IP65
Electrical connection technology Plug
Material information RoHs compliant
Corrosion resistant class KBK 2 - moderate corrosion stress
Permission RCM mark,
c UL us - Recognized (OL)
CE certificate (see declaration of conformity) to EU EMC directive,
to EU low voltage directive
Nominal voltage DC [V] 565
Winding switching type Star internal
Number of pole pairs 6
Standstill torque [Nm] 11,08
Nominal torque [Nm] 7,70
Peak torque [Nm] 27,0
Nominal rotational speed [1/min] 3.900
Max. speed [1/min] 4.510
Nominal performance motor [W] 3.140
Nominal current motor [A] 5,23
Peak current [A] 24,4
Motor constant [Nm/A] 1,470
Voltage constant phase-phase [mVmin] 88,71
Winding resistance phase-phase [Ohm] 1,600
Winding inductivity phase-phase [mH] 9,01
Total output moment of gyration [kg/cm²] 8,000
Permitted axial shaft loading [N] 200
Permitted radial shaft loading [N] 780
Rotor position transducer Resolver
Rotor position transducer interface SIN/COs analogue signals
Rotor position transducer measurement principle Inductive
MTTF, part component 114 years, rotor position sensor
MTTFd, part component 228 years, rotor position sensor
Further information:
{{ $t('shop.all.gewicht') }} 10 kg / pcs
{{ $t('shop.all.gtin') }} 4052568241629
{{ $t('shop.display.artikel.zollwarennummer') }} 85015220
{{ $t('shop.all.hersteller') }} Festo