Data sheet

EMMS-AS-140-SK-HV-RR (1574638) servo motor
{{ $t('shop.all.artikelnummer') }}:
OT-FESTO038072
Example illustration
{{ $t('shop.display.artikel.eigenschaften_headline') }}
ambient temperature [°C] -40 to 40
Bearing temperature [°C] -20 to 60
Relative humidity 0 - 90 %
Complies to standard IEC 60034
Insulation protection class F
Measurement class according to DIN 60034-1 S1
Temperature monitoring PTC resistance
Protection category IP54
Electrical connection technology Plug
Material information RoHs compliant
Corrosion resistant class KBK 2 - moderate corrosion stress
Permission RCM mark,
c UL us - Recognized (OL)
CE certificate (see declaration of conformity) to EU EMC directive,
to EU low voltage directive
Nominal voltage DC [V] 565
Winding switching type Star internal
Number of pole pairs 6
Standstill torque [Nm] 11,08
Nominal torque [Nm] 7,70
Peak torque [Nm] 27,0
Nominal rotational speed [1/min] 3.900
Max. speed [1/min] 4.510
Nominal performance motor [W] 3.140
Nominal current motor [A] 5,23
Peak current [A] 24,4
Motor constant [Nm/A] 1,470
Voltage constant phase-phase [mVmin] 88,71
Winding resistance phase-phase [Ohm] 1,600
Winding inductivity phase-phase [mH] 9,01
Total output moment of gyration [kg/cm²] 8,000
Permitted axial shaft loading [N] 200
Permitted radial shaft loading [N] 780
Rotor position transducer Resolver
Rotor position transducer interface SIN/COs analogue signals
Rotor position transducer measurement principle Inductive
MTTF, part component 114 years, rotor position sensor
MTTFd, part component 228 years, rotor position sensor
Shaft design feather key DIN 6885,
A 8 x 7 x 40
Further information:
{{ $t('shop.all.gewicht') }} 10 kg / pcs
{{ $t('shop.all.gtin') }} 4052568241568
{{ $t('shop.display.artikel.zollwarennummer') }} 85015220
{{ $t('shop.all.hersteller') }} Festo
Figure
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Our products arid goods are generally only intended for industrial and commercial uses.
As of: 08.12.2025