Data sheet

CAMC-G-S3 (1501331) safety module
Item number:
OT-FESTO057257
Example illustration
Properties
Ma­te­r­ial in­for­ma­tion LABS con­tain­ing ma­te­ri­als in­cluded,
RoHs com­pli­ant
Nom­i­nal volt­age logic sup­ply DC [V] 24
Nom­i­nal op­er­at­ing volt­age DC [V] 24
Nom­i­nal cur­rent logic sup­ply [A] 0,15
Per­mit­ted range logic volt­age ± 20 %
Power input logic sup­ply with­out park­ing brake [A] 0,20
Short cir­cuit re­sis­tance Yes, ex­cep­tion: Con­tact C1/C2
Cur­rent car­ry­ing ca­pac­ity at 40°C [A] 0,2
Fuse (short cir­cuit) no
De­sign dig­i­tal out­put Po­ten­tial free sig­nal con­tact,
3 se­cure, 2-​channel semi/con­duc­tor out­puts
Quan­tity dig­i­tal logic in­puts 10
Dig­i­tal out­puts, switch­ing logic Hal­bleit­er­ausgänge: para­me­trier­bar PNP (pluss­chal­tend) 2-​kanalig äquiv­a­lent / an­ti­va­lent
Di­men­sions W x L x H 112.2 mm x 99.1 mm x 28.7 mm
LED dis­play prod­uct spe­cific Error (red),
Nor­mal mode (Green),
Safe con­di­tions (yel­low)
Safety func­tion Safe switched off torque (STO),
Safe lim­ited speed (SLS),
Safe brak­ing con­trols (SBC),
Safe op­er­at­ing stop (SOS),
Safe stop 1 (SS1),
Safe stop 2 (SS2),
Safe speed range (SSR),
Safe speed mon­i­tor­ing (SSM)
Prob­a­bil­ity of Fail­ure per Hour in [1/h]. 9.5e-​009
Proof test in­ter­val [A] 20
Hard­ware error tol­er­ance 1
SFF Safe Fail­ure Frac­tion [%] 99,5
Cer­ti­fied for safety func­tion to ISO 13849 and IEC 61508 (SIL) Prod­uct can be in­serted into SRP/CS to SIL 3 High De­mand
Safety In­tegrity Level (SIL) Safe switched off torque (STO) / SIL 3,
Safe brak­ing con­trols (SBC) / SIL 3,
Safe lim­ited speed (SLS) / SIL 3,
Safe op­er­at­ing stop (SOS) / SIL 3,
Safe stop 1 (SS1) / SIL 3,
Safe stop 2 (SS2) / SIL 3,
Safe speed mon­i­tor­ing (SSM) / SIL 3,
Safe speed range (SSR) / SIL 3
Per­for­mance Level (PL) Sicher abgeschal­tetes Mo­ment (STO) / Kat­e­gorie 4, Per­for­mance Level e,
Sichere Brem­se­nans­teuerung (SBC) / Kat­e­gorie 4, Per­for­mance Level e,
Sicher be­gren­zte Geschwindigkeit (SLS) / Kat­e­gorie 3, Per­for­mance Level e,
Sicherer Be­trieb­shalt (SOS) / Kat­e­gorie 3, Per­for­mance Level e,
Sicherer Stopp 1 (SS1) / Kat­e­gorie 3, Per­for­mance Level e,
Sicherer Stopp 2 (SS2) / Kat­e­gorie 3, Per­for­mance Level e,
Sichere Geschwindigkeitsüberwachung (SSM) / Kat­e­gorie 3, Per­for­mance Level e,
Sicherer Geschwindigkeits­bere­ich (SSR) / Kat­e­gorie 3, Per­for­mance Level e
Di­ag­nose de­gree of cov­er­age [%] 97,5
Cer­ti­fied for safety func­tion to ISO 13849 (PL) Prod­uct can be in­serted into SRP/CS to cat­e­gory 4, PL e
Per­mis­sion TÜV
CE cer­tifi­cate (see de­c­la­ra­tion of con­for­mity) to EU EMC di­rec­tive,
to EU ma­chin­ery di­rec­tive
Cer­ti­fied award­ing point 01/205/5165.02/19,
TÜV Rhein­land
Bear­ing tem­per­a­ture [°C] -25 to 55
Rel­a­tive hu­mid­ity 5 - 90 %,
Not con­dens­ing
Pro­tec­tion cat­e­gory IP20,
In mounted con­di­tion
am­bi­ent tem­per­a­ture [°C] 0 to 40
Fas­ten­ing type Plug-​in mod­ule for CMMP-​AS... -M3
in­stal­la­tion po­si­tion ar­bi­trary
Wire ends Wire end sleeve
Con­nec­tion cross-​section [mm²] 0.25 to 0.5
Elec­tri­cal con­nec­tion Screw clamp,
Plug straight
Dis­play LED green / yel­low / red
Op­er­at­ing el­e­ment Dip switch
Logic input spec­i­fi­ca­tion IEC 61131-​2, Typ 3
Prop­er­ties logic in­puts 4 sichere, 2-​kanalige Eingänge äquiv­a­lent / an­ti­va­lent schal­tend Tes­tim­pulse kon­fig­urier­bar Funk­tion kon­fig­urier­bar,
6 sichere, 1-​kanalige Eingänge Tes­tim­pulse kon­fig­urier­bar
Work area logic input [V] 13 to 28.8
Max. nom­i­nal input cur­rent [A] 0,015
De­bounce time in­puts [ms] 0,3
Cur­rent car­ry­ing ca­pac­ity per out­put [mA] 50
Max. cur­rent dig­i­tal logic out­puts [mA] 50
Out­put fuses Short and cross-​connection mon­i­tor­ing
Min­i­mum cycle time [ms] 2
Pa­ra­me­ter­is­ing Via Safe­ty­Tool
Further information:
Weight 240 g / pcs
GTIN 4052568237950
Customs duty number 85389099
Manufacturer Festo
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
As of: 20.05.2025