CPX-F8DE-P (2597424) input module
Item number:
OT-FESTO058228
Example illustration
Properties
Di­men­sions W x L x H 50 mm x 107 mm x 55 mm,
(Incl. link­ing block and con­nec­tors)
Di­ag­no­sis Un­ter­span­nung,
Kom­mu­nika­tion,
Übertem­per­atur,
Draht­bruch pro Kanal,
Kurz­schluss pro Kanal,
Prozess­wert­fehler,
Quer­schluss pro Kanal,
Selb­sttest,
Überspan­nung
Op­er­at­ing el­e­ment DIL switch
LED dis­plays 1 Failsafe-​Protokoll aktiv,
1 Sam­mel­diag­nose,
8 Kanal­diag­nose,
8 Kanal­sta­tus
Op­er­at­ing volt­age range DC [V] 20.4 to 28.8
In­trin­sic power input at op­er­at­ing volt­age Type 35 mA For elec­tron­ics
Nom­i­nal op­er­at­ing volt­age DC [V] 24
Po­ten­tial sep­a­ra­tion chan­nel - chan­nel no
Cor­ro­sion re­sis­tant class KBK (In in­te­grated con­di­tion),
1 - low cor­ro­sion stress
Bear­ing tem­per­a­ture [°C] -20 to 70
Pro­tec­tion cat­e­gory De­pends on con­nec­tion block
am­bi­ent tem­per­a­ture [°C] -5 to 50
Max. ad­dress vol­ume out­puts [Byte] 7
Max. ad­dress vol­ume in­puts [Byte] 6
Max. line length 200 m
Ma­te­r­ial in­for­ma­tion RoHs com­pli­ant
Quan­tity in­puts 8
Char­ac­ter­is­tic curves in­puts to IEC 61131-​2 type 2
Switch­ing logic in­puts PNP (Pos­i­tive switch­ing)
Safety func­tion Safe record­ing and analy­sis of input con­di­tions
Safety In­tegrity Level (SIL) Safe record­ing and analy­sis of input con­di­tions ac­cord­ing to EN62061 to SIL CL3,
Safe record­ing and analy­sis of input con­di­tions ac­cord­ing to EN61508 to SIL3
Per­for­mance Level (PL) Safe record­ing and analy­sis of input con­di­tions ac­cord­ing to ISO13849 to Cat.4 and PL e
Max. cu­mu­la­tive cur­rents per mod­ule [A] 3
resid­ual rip­ple 2 Vss within volt­age range
Per­mis­sion c UL us - Rec­og­nized (OL)
CE cer­tifi­cate (see de­c­la­ra­tion of con­for­mity) to EU ma­chin­ery di­rec­tive
Cer­ti­fied award­ing point 01/205/5444.00/15
Prob­a­bil­ity of Fail­ure per Hour in [1/h]. 1e-​009
Further information:
Weight 110 g / pcs
GTIN 4052568265366
Customs duty number 85389099
Manufacturer Festo
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
As of: 05.07.2025