CPX-CTEL-2-M12-5POL-LK (2900543) electrical interface
Item number:
OT-FESTO058505
Example illustration
Properties
Di­men­sions W x L x H 50 mm x 107 mm x 55 mm,
(Incl. link­ing block)
Di­ag­no­sis Un­ter­span­nung,
Kom­mu­nika­tions­fehler,
Kurz­schluss Mod­ule,
Mod­u­lo­ri­en­tierte Di­ag­nose
Pa­ra­me­ter­is­ing Di­ag­no­sev­er­hal­ten,
Fail­safe pro Kanal,
Forcen pro Kanal,
Idle Mode pro Kanal,
Modul-​Parameter
Op­er­at­ing el­e­ment DIL switch
LED dis­plays PL: Load sup­ply,
PS: Elec­tronic sup­ply, sen­sor sup­ply,
Col­lec­tive di­ag­no­sis,
X1: Sys­tem sta­tus IO link port 1,
X1: Sys­tem sta­tus IO link port 2
Op­er­at­ing volt­age range DC [V] 18 to 30
In­trin­sic power input at op­er­at­ing volt­age Type 65 mA
Nom­i­nal op­er­at­ing volt­age DC [V] 24
Power black­out bridg­ing [ms] 10
Po­ten­tial sep­a­ra­tion chan­nel - in­ter­nal bus Yes, for in­ter­me­di­ate feed
Po­ten­tial sep­a­ra­tion chan­nel - chan­nel no
Cor­ro­sion re­sis­tant class KBK (In in­te­grated con­di­tion),
1 - low cor­ro­sion stress
Bear­ing tem­per­a­ture [°C] -20 to 70
Pro­tec­tion cat­e­gory IP65,
IP67
am­bi­ent tem­per­a­ture [°C] -5 to 50
Max. ad­dress vol­ume out­puts [Byte] 32
Max. ad­dress vol­ume in­puts [Byte] 32
Re­port IO-​Link
Max. line length 20 m
Elec­tri­cal con­nec­tion M12,
5 pin,
A-​coded,
2x socket
Ma­te­r­ial in­for­ma­tion RoHs com­pli­ant
Hous­ing ma­te­r­ial PC,
PA re­in­forced
IO-​Link, re­port Mas­ter V 1.0
IO-​Link, com­mu­ni­ca­tion mode COM1 (4,8 kBaud), COM2 (38,4 kBaud), COM3 (230,4 kBaud)
IO-​Link, port type AB
IO-​Link, num­ber of ports 2
IO-​Link, process data width OUT Pa­ra­me­ter­is­able 4/4 to 16/16 Bytes
IO-​Link, process data width IN Pa­ra­me­ter­is­able 4/4 to 16/16 Bytes
IO-​Link, min­i­mum cycle time Min. 1 ms per 1 Byte process data
IO-​Link Mas­ter, out­put cur­rent 1,6 A PL / Port,
1,6 A PS / Port
Further information:
Weight 135 g / pcs
GTIN 4052568255534
Customs duty number 85389099
Manufacturer Festo
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
As of: 20.07.2025