| Permission |
RCM mark, c UL us - Listed (OL) |
| CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU-RoHS Directive |
| KC-mark | KC-EMV |
| Certified awarding point | UL E322346 |
| Material information | RoHs compliant |
| Measured parameter | Relative pressure |
| Measurement process | Piezoresistive pressure sensor |
| Druckmessbereich Anfangswert (MPa) [MPa] | 0 |
| Pressure measurement range starting value [bar] | 0 |
| Druckmessbereich Anfangswert (psi) [psi] | 0 |
| Druckmessbereich Endwert (MPa) [MPa] | 1,0 |
| Pressure measurement range end value [bar] | 10 |
| Druckmessbereich Endwert (psi) [psi] | 145,0 |
| Overload range [bar] | 15 |
| Overload pressure [MPa] | 1,5 |
| Überlastdruck (psi) [psi] | 217,5 |
| Operating medium |
Compressed air to ISO 8573-1:2010 [7:4:4], Inert gases |
| Information about operating and control medium | Oiled operation possible |
| Medium temperature [°C] | 0 to 50 |
| ambient temperature [°C] | 0 to 50 |
| Accuracy FS [%FS] | 1,5 |
| Repeatability in ± %FS [%FS] | 0,3 |
| Temperature coefficient in ± %FS/K [%FS/K] | 0,05 |
| Control output | 2 x PNP or 2 x NPN switchable |
| Switch function |
Window comparator, Threshold comparator, Auto difference monitoring |
| Switching element function | Opener/closer switchable |
| Max. output current [mA] | 100 |
| Analogue output |
0 - 10 V, 4 - 20 mA, 1 - 5 V |
| Max. load resistance current output [Ohm] | 500 |
| Min. load resistance voltage output [kOhm] | 20 |
| Short circuit resistance | yes |
| Report | IO-Link |
| IO-Link, report | Device V 1.1 |
| IO-Link, profile | Smart sensor profile |
| IO-Link, function classes |
Teach channel, Diagnosis, Identification, Binary data channel (BDC), Process data variables (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO mode support | yes |
| IO-Link, port type | A |
| IO-Link, process data width OUT | 0 Bytes |
| IO-Link, process data width IN | 2 Bytes |
| IO-Link, process data contents IN |
14 bit PDV (pressure measurement), 2 bit BDC (pressure monitoring) |
| IO-Link, minimum cycle time | 3 ms |
| IO-Link, data memory needed [Byte] | 500 |
| Operating voltage range DC [V] | 15 to 30 |
| Reverse polarity protection | for all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connection technology | Wiring diagram L1J |
| Electrical connection 1, number of pins / wires | 4 |
| Fastening type |
Front panel integration, With Wall / flat holder |
| installation position | arbitrary |
| Pneumatic connection | female thread M5 |
| Housing material | PA reinforced |
| From medium contacting materials |
FPM, NBR, PA-verstärkt, Messing, vernickelt |
| Display type | Illuminating LCD |
| Presentable unit(s) |
MPa, bar, inchH2O, inchHg, kPa, kgf/cm², mbar, mmHg, psi |
| Setting options |
IO-Link, Teach-In, über Display und Tasten |
| Tamper-proof fuse |
IO-Link, PIN code |
| Settings range threshold value [%] | 0 to 100 |
| Settings range hysteresis [%] | 0 to 90 |
| Protection category | IP40 |
| Corrosion resistant class KBK | 2 - moderate corrosion stress |
| {{ $t('shop.all.gewicht') }} | 60 g / pcs |
| {{ $t('shop.all.gtin') }} | 4052568284794 |
| {{ $t('shop.display.artikel.zollwarennummer') }} | 90262020 |
| {{ $t('shop.all.hersteller') }} | Festo |