| Permission |
RCM mark, c UL us - Listed (OL) |
| CE certificate (see declaration of conformity) |
acc. to EU-EMV Directive, acc. to EU-RoHS Directive |
| KC-mark | KC-EMV |
| Certified awarding point | UL E322346 |
| Material information | RoHs compliant |
| Measured parameter |
Mass flow, Volume flow rate |
| Flow direction | Uni-directional |
| Measurement principle | Thermic |
| Measurement process | Heat Transfer |
| Flow measurement range starting value [l/min] | 0,100 |
| Flow measurement range end value [l/min] | 5,0 |
| Operating pressure [bar] | -0.9 to 10 |
| Operating medium |
Druckluft nach ISO 8573-1:2010 [6:4:4], Stickstoff, Argon |
| Medium temperature [°C] | 0 to 50 |
| ambient temperature [°C] | 0 to 50 |
| Nominal temperature [°C] | 23 |
| Accuracy flow value | ± (2% o.m.v. + 1% FS) |
| Repeatability null point in ± %FS [%FS] | 0,2 |
| Repeatability clamp in ± %FS [%FS] | 0,8 |
| Temperature coefficient clamp in ± %FS/K | type 0,15%FS/K |
| Pressure dependency clamp in ± %FS/bar [%FS/b.] | 1 |
| Control output | 2 x PNP or 2 x NPN switchable |
| Switch function |
Window comparator, Threshold comparator, Auto difference monitoring |
| Switching element function | Opener/closer switchable |
| Max. output current [mA] | 100 |
| Analogue output |
0 - 10 V, 4 - 20 mA, 1 - 5 V |
| Flow characteristic curve starting value [l/min] | 0 |
| Flow characteristic curve end value [l/min] | 5,0 |
| Max. load resistance current output [Ohm] | 500 |
| Min. load resistance voltage output [kOhm] | 20 |
| Short circuit resistance | yes |
| Overload resistant | Available |
| Report | IO-Link |
| IO-Link, report | Device V 1.1 |
| IO-Link, profile | Smart sensor profile |
| IO-Link, function classes |
Teach channel, Diagnosis, Identification, Binary data channel (BDC), Process data variables (PDV) |
| IO-Link, communication mode | COM2 (38.4 kBaud) |
| IO-Link, SIO mode support | yes |
| IO-Link, port type | A |
| IO-Link, process data width IN | 3 Bytes |
| IO-Link, process data contents IN |
1 bit BDC (Volume monitoring), 14 bit PDV (Flow measurement), 2 bit BDC (Flow monitoring) |
| IO-Link, service data unit IN | 32 bit Volumen-/Massemesswert |
| IO-Link, minimum cycle time | 4 ms |
| IO-Link, data memory needed [Byte] | < 0,5 kB |
| Operating voltage range DC [V] | 22 to 26 |
| Empty run current [mA] | <= 25 mA |
| Reverse polarity protection | for all electrical connections |
| Electrical connection 1, connection type | Plug |
| Electrical connection 1, connection technology | M8x1 A coded to EN 61076-2-104 |
| Electrical connection 1, number of pins / wires | 4 |
| Fastening type | With Accessories |
| installation position | arbitrary |
| Pneumatic connection | For hose exterior diameter 6 mm |
| Pneumatic connection, connection outlet | straight |
| Housing material | PA reinforced |
| From medium contacting materials |
NBR, high-alloyed stainless steel, PA reinforced, Alu wrought alloy, anodised, Epoxy resin, Silicon, Silicon nitride |
| Display type | Illuminating LCD Multiple |
| Presentable unit(s) |
g, g/min, l, l/h, l/min, scft, scft/h, scft/min |
| Setting options |
IO-Link, Teach-In, über Display und Tasten |
| Tamper-proof fuse |
IO-Link, PIN code |
| Protection category | IP40 |
| Pressure drop [mbar] | < 5 mbar |
| Protection class | III |
| Corrosion resistant class KBK | 2 - moderate corrosion stress |
| {{ $t('shop.all.gewicht') }} | 80 g / pcs |
| {{ $t('shop.all.gtin') }} | 4052568295509 |
| {{ $t('shop.display.artikel.zollwarennummer') }} | 90268020 |
| {{ $t('shop.all.hersteller') }} | Festo |