| Valve function | 3-way proportional pressure regulator valve |
| Construction set up |
Piston pusher, With Integrated pressure sensors |
| Control type | Direct |
| Actuation type | Electrical |
| Reset mode | Spring magnetic |
| Flow direction | Not reversible |
| installation position | arbitrary |
| Sealing principle | Hard |
| Nominal width [mm] | 6 |
| Short circuit resistance | yes |
| Display type | LED |
| Normal nominal flow [l/min] | 725 |
| Operating pressure [bar] | 4 to 8 |
| Typische Absinkgeschwindigkeit [mm/s] | 15 |
| Hinweis zur Absinkgeschwindigkeit | Bei Betätigung der Handentlüftung mit Zylinderdurchmesser 80 mm, Übersetzungsverhältnis 1:1 und 100 kg Lastmasse. |
| ambient temperature [°C] | 0 to 50 |
| Operating medium | Compressed air to ISO 8573-1:2010 [6:4:4] |
| Information about operating and control medium |
Oiled operation not possible, Maximum particle size 5 µm |
| Protection category | IP65 |
| Information about protection category | In mounted condition |
| Permission | RCM mark |
| KC-mark | KC-EMV |
| CE certificate (see declaration of conformity) | to EU EMC directive |
| Material information | RoHs compliant |
| Oscillation strength | Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27 |
| Corrosion resistant class KBK | 1 - low corrosion stress |
| User information | Das Produkt ist ausschließlich für industrielle Zwecke geeignet. In Wohnbereichen müssen eventuell Maßnahmen zur Funkentstörung getroffen werden. |
| Nominal operating voltage DC [V] | 24 |
| Operating voltage range DC [V] | 21.6 to 26.4 |
| residual ripple | 5 % |
| Max. power input [A] | 1,2 |
| Power input | 120 mA |
| Reverse polarity protection | for operating voltage |
| Power-on time | 100 % |
| Max. electrical power consumption [W] | 33,5 |
| Diagnose function | Display via LED |
| Max. line length | 30 m |
| Fieldbus interface, connection type | Plug |
| Fieldbus interface, connection technology | M12x1 A coded to EN 61076-2-101 |
| Fieldbus interface, number of pins / wires | 5 |
| Fieldbus interface, report | CAN-Bus mit Festo Protokoll |
| Elektrischer Anschluss Antrieb, Anschlussart | socket / container / …. |
| Elektrischer Anschluss Antrieb, Anschlusstechnik | M12x1 A coded to EN 61076-2-101 |
| Elektrischer Anschluss Antrieb, Anzahl Pole/Adern | 8 |
| Elektrischer Anschluss Ventil, Anschlussart | Plug |
| Elektrischer Anschluss Ventil, Anschlusstechnik | Anschlussbild Form C nach Industriestandard 9,4 mm |
| Elektrischer Anschluss Ventil, Anzahl Pole/Adern | 2 |
| Fastening type | Direktbefestigung über M5-Gewinde |
| Pneumatic connection 1 | G3/8 |
| Pneumatic connection 2 | G3/8 |
| Pneumatic connection 3 | G3/8 |
| Pneumatischer Anschluss Bedienelement | G1/8 |
| Housing material | Aluminium wrought alloy, anodised |
| Seals material |
FKM, HNBR, NBR |
| Weight | 1,6 kg / pcs |
| GTIN | 4052568445812 |
| Tariff No. | 84812090 |
| Manufacturer | Festo |