MDH-3/2-230VAC (119602) pilot valve
Item number:
OT-FESTO009463
Example illustration
Properties
Valve func­tion 3/2 closed mono­stable
Ac­tu­a­tion type Elec­tri­cal
Build.width [mm] 30
Nor­mal nom­i­nal flow [l/min] 50
Op­er­at­ing pres­sure [bar] 1 to 16
Con­struc­tion set up Plate seat
Reset mode Me­chan­i­cal spring
Pro­tec­tion cat­e­gory IP65
Nom­i­nal width [mm] 1,3
Pitch di­men­sion [mm] 42
Ex­haust func­tion Can­not be throt­tled
Based on stan­dard ISO 15218
Seal­ing prin­ci­ple Soft
in­stal­la­tion po­si­tion ar­bi­trary
Com­plies to stan­dard ISO 15218
Hand as­sist ac­tu­a­tion ten­ta­tive
Con­trol type Di­rect
Flow di­rec­tion Not re­versible
Überdeck­ung neg­a­tive Überdeck­ung
Shift­ing time off [ms] 9
Shift­ing time on [ms] 11
Power-​on time 100 %
Coil char­ac­ter­is­tic value 110 V DC: 6,3 W,
230 V AC: 50 Hz, pull-​in power 14.5 VA, hold­ing power 10.5 VA,
230 V AC: 60 Hz, pull-​in power 12.0 VA, hold­ing power 7.6 VA
Per­mit­ted volt­age os­cil­la­tions ± 10 %
Op­er­at­ing medium Com­pressed air to ISO 8573-​1:2010 [7:4:4]
In­for­ma­tion about op­er­at­ing and con­trol medium Oiled op­er­a­tion pos­si­ble (re­quired in fur­ther op­er­a­tions)
Cor­ro­sion re­sis­tant class KBK 2 - mod­er­ate cor­ro­sion stress
Medium tem­per­a­ture [°C] -15 to 80
am­bi­ent tem­per­a­ture [°C] -15 to 50
Elec­tri­cal con­nec­tion Wiring di­a­gram Form A acc. to EN 175301-​803,
acc. to DIN EN 175301-​803
Fas­ten­ing type on con­nec­tion plate,
With through­way bores
Pneu­matic con­nec­tion 1 Con­nec­tion plate
Pneu­matic con­nec­tion 2 Con­nec­tion plate
Pneu­matic con­nec­tion 3 Not recorded
Ma­te­r­ial in­for­ma­tion RoHs com­pli­ant
Seals ma­te­r­ial FPM
CE cer­tifi­cate (see de­c­la­ra­tion of con­for­mity) to EU low volt­age di­rec­tive
Per­mit­ted fre­quency os­cil­la­tions ± 10 %
Further information:
Weight 155 g / pcs
GTIN 4052568068257
Customs duty number 84812090
Manufacturer Festo
Landefeld Druckluft und Hydraulik GmbH · Konrad-Zuse-Straße 1 · 34123 Kassel · Germany
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
As of: 29.04.2025