Version:
Self-relieving pressure regulator

Materials:
Body: die-cast zinc Z410 (model series 4 & 5: aluminium), spring hood: POM, diaphragms and seals: NBR

Temperature range:
-10 to +60 °C

Pressure gauge connection (does not apply to pressure regulators with continuous pressure supply):
G 1/4" (model series 0: G 1/8")

Media:
Oiled and unoiled compressed air, neutral gasses

Advantages:
•Automatic venting in the event of overpressure on the secondary side,
•Easy assembly of individual components using coupling kits within a model series and thread size,
•Hand wheel can be locked by pressing down on it


Application:
The remote controlled pressure regulator is used if the pressure regulator has to be used at inaccessible locations (e.g. in hazardous or ceiling areas). The setting is made using a pilot pressure regulator that can be placed anywhere. The regulated pressure corresponds to the pressure of the remote controlled bore.

Materials:
Body: die-cast zinc Z410 (model series 5: aluminium), top cover: brass, diaphragms and seals: NBR

Scope of delivery:
Pressure regulator incl. 50 mm pressure gauge

Own air consumption:
Multifix 1 & 2: none, Multifix 4: max. 1.5 l/min, Multifix 5: max. 0.5 l/min

ATEX:
Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU (not model series 4)

Advantages:
•Remote pressure control by a pilot regulator (when using a precision regulator with feedback connection as pilot, a very precise pressure setting is possible)
Properties
Model se­ries Mul­ti­fix 1
Thread G 1/4"
Pres­sure reg­u­la­tion range [bar] 0,5 - 16
Flow* [l/min] 2100
Pres­sure gauge dis­play [bar] 0 - 25
Mount­ing brack­ets W 1
Cou­pling kit KP 1
input pres­sure [bar] max. 16
H [mm] 69
H1 [mm] 42
L [mm] 48
Thread con­trol con­nec­tion G 1/8"
Further information on RF14
Weight 420 g / pcs
GTIN 4050571577391
Customs duty number 84811099
RoHS compliant Yes
Documents
*measured at P1 = 10 bar, P2 = 6.3 bar and 1 bar pressure drop

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.