Design |
round
|
Complies to standard |
EN 60947-5-2
|
Permission |
RCM mark, c UL us - Listed (OL)
|
CE certificate (see declaration of conformity) |
to EU EMC directive, to EU low voltage directive
|
Material information |
Copper and PTFE-free
|
Measurement principle |
Inductive
|
Measurement switching distance [mm] |
5
|
Secured safety distance [mm] |
4,05
|
Reduction factors |
aluminium = 0,4, stainless steel St 18/8 = 0,7, Copper = 0.3, brass = 0,4, Steel pc. 37 = 1.0
|
ambient temperature [°C] |
-25 to 85
|
Repeatability [mm] |
0,15
|
Control output |
Contactless 2-wire
|
Switching element function |
NO contact
|
Hysteresis [mm] |
0.04 to 1.15
|
Max. switching frequency DC [Hz] |
490
|
Max. switching frequency AC [Hz] |
25
|
Max. output current [mA] |
300
|
Voltage drop [V] |
<= 8 V
|
Minimum load current [mA] |
5
|
Short circuit resistance |
no
|
Operating voltage range AC [V] |
20 to 265
|
Operating voltage range DC [V] |
20 to 320
|
Network frequency [Hz] |
50
|
Empty run current [mA] |
<= 1,5 mA
|
Reverse polarity protection |
for all electrical connections
|
Electrical connection |
2-wire, cable
|
size |
M18
|
Fastening type |
With locking nut
|
Torque [Nm] |
30
|
Integration type |
flush
|
Housing material |
PA, brass, nickel-plated
|
Switching status indicator |
LED yellow
|
Protection category |
IP67
|
Corrosion resistant class KBK |
1 - low corrosion stress
|
Cable length [MTR] |
2,5
|
Cable sleeve material |
TPE-U(PUR)
|
Insulation sleeve material |
PVC
|
Ambient temperature for moving cable placements [°C] |
-5 to 50
|